Guides for plants that run on diesel backup
What a unit from your generator really costs, how to read the two numbers on your DG panel that decide everything, and where a battery fits and where it does not.
Battery energy storage for factories in India: a plain guideWhat a commercial and industrial battery is, how long it lasts, how it takes over when the grid fails, how it should be sized, what the CEA's new safety rules require, and how buying one works.Battery storage vs diesel generator: why a factory needs bothA battery is instant and costs far less per unit. A genset runs for as long as there is fuel. For most factories the right answer is the battery for short cuts and the genset for long ones.What does a unit from your DG set really cost?About ₹27.70 a kWh at our reference plant, against ₹10 for grid power. Here is the arithmetic behind that figure and how to work out your own from litres and kWh.How to read your DG set's start counter and engine hoursTwo numbers on your generator's controller tell you how often your power fails and how long it stays off. Here is where to find them, the arithmetic, and the corrections that keep it honest.GRAP and diesel generators in Delhi NCR: what the rules say nowChecked against CAQM's own documents on 11 October 2026. DG rules now sit in GRAP Stage I, compliant sets carry no daily hour limit, and older sets need dual fuel or a certified emission control device, depending on size.How much diesel does a DG set use per hour?A table of litres per hour by kVA and load, worked out in the open, a public reference range from the Bureau of Energy Efficiency, and why your own logbook beats both.How to find out how often the power fails at your factoryYour DISCOM's reliability indices, its outage reports, an RTI request for your feeder's record and the start counter on your own genset: what each one tells you and what it leaves out.CEA safety regulations for battery energy storage in IndiaRead from the gazette on 14 October 2026: the new Chapter XA, when it comes into force, which installations it covers, what it requires, what it leaves to standards not yet listed, and the state approvals that apply today.Maximum demand charges and a factory battery: what to checkA battery that charges at the wrong moment can add to your recorded maximum demand. How MD is measured and billed, what time of day tariffs change, and why twelve months of bills come before any figure.A CFO's guide to the diesel generator line in your budgetDiesel backup is an operating cost that comes back every year with no ceiling. This is how to measure it, compare it with a one-time battery, and plan the decision before the next season of power cuts.How to reduce your diesel generator cost: what works, and whereSome of these cost nothing but attention. Others need capital. All of them depend on how often your power fails and how long it stays off, so measure that first.Why rooftop solar stops during a power cut, and what changes itBijli gayi, solar bhi gaya. Why grid-tied solar shuts down in a cut, why the genset cannot take its output, what a grid-forming battery changes, and why we keep solar outside the diesel saving guarantee.UPS vs inverter vs battery energy storage: which does a factory need?Three machines that all hold a battery, built for three different jobs. How each one switches over, how long it carries a load, and why most factories end up with more than one.
Run your own numbers
Six inputs, two minutes, and the full working shown.